Messages
Message 1 (Error)
Sequence [1] includes the [2] action. Use of the [2] action requires a waiver from Microsoft.
[2] is the name of an action in your project, and [1] is the name of the sequence that contains that action.
Message 2 (Error)
Control [1] on Dialog [2] runs the [3] action. Use of the [3] action requires a waiver from Microsoft.
[3] is the name of an action in your project. [2] is the name of the control that includes an event that launches that action. [2] is the name of the dialog that has the control.
Description
ISICE17 verifies that the installation does not use an action to force a reboot. Currently, the only action that is validated is ForceReboot.
Corrective Action
The errors are displayed to inform you that if you want to have your product qualify for the Windows logo program but you keep the specified action in your installation, you may need to obtain a waiver from Microsoft.
To resolve these validation errors, remove the action from sequence or dialog that is mentioned in the message.
Ensure that your project includes the MsiRMFilesInUse dialog to minimize system reboots, and that your application has been properly instrumented to use the Restart Manager API. For more information, see Minimizing Reboots on Windows Vista and Later Systems.