Message (Error)
The standard MSI table [1] does not match the MSI schema defined in schema.msi.
[1] is the name of a table in your project.
Description
ISICE04 verifies that your installation does not add custom table columns to standard tables. Adding columns to standard tables is reserved for future versions of Windows Installer.
Corrective Action
To resolve this error, remove any custom table columns that were added to the table that is mentioned in the error message. You can do this by exporting the table from the Direct Editor, editing the table in a text editor, and importing the revised table.
See Also
Database Tables (Windows Installer Help Library)
Requirements for the Windows Logo Program