InstallShield 2019
Project • This information applies to the following project types:
• | InstallScript |
• | InstallScript MSI |
Setup.log is the default name for the silent installation log file—generated when the end user runs Setup.exe with the /s argument—and it is by default created in the directory containing the response file Setup.iss. You can specify a different name and location for Setup.log using the /f1 and /f2 switches to Setup.exe.
The Setup.log file contains three sections. The first section, [InstallShield Silent], identifies the version of InstallShield Silent used in the silent installation. It also identifies the file as a log file.
The second section, [Application], identifies the installed application’s name and version, and the company name.
The third section, [ResponseResult], contains the result code indicating whether the silent installation succeeded. An integer value is assigned to the ResultCode keyname in the [ResponseResult] section. The installation places one of the following return values in the ResultCode key.
Project • Note that in an InstallScript MSI installation, there is no initialization process for reading or writing response files. As a result, the only errors that may occur for InstallScript MSI installation are -3 for silent installations and -6 for recording installations. Thus, the following table shows applicable project types where appropriate.
Result Code |
Project Type |
Description |
0 |
InstallScript, InstallScript MSI |
Success. |
-1 |
InstallScript |
General error. |
-2 |
InstallScript |
Invalid mode. |
-3 |
InstallScript, InstallScript MSI |
Required data not found in the Setup.iss file. |
-4 |
InstallScript |
Not enough memory available. |
-5 |
InstallScript |
File does not exist. |
-6 |
InstallScript, InstallScript MSI |
Cannot write to the response file. |
-7 |
InstallScript |
Unable to write to the log file. |
-8 |
InstallScript |
Invalid path to the InstallShield Silent response (.iss) file. |
-9 |
InstallScript |
Not a valid list type (string or number). |
-10 |
InstallScript |
Data type is invalid. |
-11 |
InstallScript |
Unknown error during setup. |
-12 |
InstallScript |
Dialog boxes are out of order. |
-51 |
InstallScript |
Cannot create the specified folder. |
-52 |
InstallScript |
Cannot access the specified file or folder. |
-53 |
InstallScript |
Invalid option selected. |
The Setup.log file for a successful silent installation appears as follows:
[Application]
Name=Sample App 3000
Version=1.00.0000
Company=Sample Software Corporation
Lang=0409
[ResponseResult]
ResultCode=0
InstallShield 2019 Help LibraryApril 2019 |