Visual Studio Project Import Errors and Warnings

InstallShield 2019

This table lists the errors and warnings that might occur when you do any of the following:

Convert a Visual Studio setup project (.vdproj) to an InstallShield Basic MSI project (.ism).
Convert a Visual Studio merge module project (.vdproj) to an InstallShield Merge Module project (.ism).
Import a Visual Studio setup or merge module project (.vdproj) into an InstallShield Basic MSI or Merge Module project (.ism).

Visual Studio Project Import Errors and Warnings

Error or Warning Number

Message

Troubleshooting Tips

-9000

An unknown exception occurred.

Check the Knowledge Base for information about this error, or request technical support.

-9001

An unknown COM exception occurred.

Check the Knowledge Base for information about this error, or request technical support.

-9002

An error occurred while loading the project %1.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9003

An error occurred while creating the project %1.

This error occurs if InstallShield cannot create a Basic MSI project from the Visual Studio setup project or a Merge Module project from the Visual Studio merge module project. InstallShield tries to create the project in the same folder that contains the Visual Studio project file (.vdproj).

To resolve this error, see if the folder that contains the Visual Studio project file is read-only, and change it to writable.

-9004

An error occurred while saving the project %1.

This error occurs if InstallShield cannot create a Basic MSI project from the Visual Studio setup project or a Merge Module project from the Visual Studio merge module project. InstallShield tries to save the project in the same folder that contains the Visual Studio project file (.vdproj).

To resolve this error, see if the folder that contains the Visual Studio project file is read-only, and change it to writable.

-9005

An error occurred while converting the project.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9006

An error occurred while determining the project type.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9007

An error occurred while parsing the section '%1'.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9008

No open brace found for the section %1 under %2.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9009

No close brace found for the section %1 under %2.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9010

An invalid entry %1 found in the section %1 under %2.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9011

An error occurred while adding the property %1 to the section %2.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9012

An error occurred while adding the section %1 to the section %2.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9013

The section %1 does not exist.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9014

An error occurred while converting the product properties.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9015

An error occurred while converting the files.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9016

The file type %1 is invalid. The file %2 was not converted.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9017

An error occurred while converting the file %1. Type: %2

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9018

An error occurred while converting the features.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9019

An error occurred while converting the feature %1.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9020

An error occurred while converting the folders.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9021

An error occurred while converting the folder %1. Type: %2

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9022

The folder type %1 is invalid. The folder %2 was not converted.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9023

An error occurred while converting the custom actions.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9024

An error occurred while converting the custom action %1. Type: %2

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9025

The custom action type %1 is invalid. The custom action %2 was not converted.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9026

A component for the source file %1 of the custom action %2 was not found.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9027

An error occurred while converting the file types.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9028

An error occurred while converting the file extension %1. Type: %2

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9029

The file extension type %1 is invalid. The file extension %2 was not converted.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9030

An error occurred while converting the verb %1. Type: %2

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9031

The verb type %1 is invalid. The verb %2 was not converted.

This error may occur if the Visual Studio project file is corrupted or if InstallShield cannot correctly read the Visual Studio project file. To resolve this error, request technical support.

-9032

A command is not specified for the file extension %1. The file extension was not converted.

This warning occurs if the Command property for the specified file type was left blank in the File Types Editor in Visual Studio. The warning alerts you that InstallShield could not configure the file extension during the conversion process.

To resolve this issue, specify a command for the file type in Visual Studio, and then convert the Visual Studio setup project to an InstallShield project. Otherwise, you can add and configure the file extension in the File Types area of the Components view in InstallShield.

-9033

A component for the command %1 of the file extension %2 not found. The file extension was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9034

An error occurred while converting the registries.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9035

An error occurred while converting the registry key %1. Type: %2

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9036

The registry key type %1 is invalid. The registry key %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9037

An error occurred while converting the registry value %1. Type: %2

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9038

The registry value type %1 is invalid. The registry value %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9039

An error occurred while converting the shortcuts.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9040

An error occurred while converting the shortcut %1. Type: %2

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9041

The shortcut type %1 is invalid. The shortcut %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9042

The shortcut target %1 is invalid. The shortcut %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9043

An error occurred while converting the launch conditions.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9044

An error occurred while converting the launch condition %1. Type: %2

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9045

The launch condition type %1 is invalid. The launch condition %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9046

An error occurred while converting the locators.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9047

An error occurred while converting the locator %1. Type: %2

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9048

The locator type %1 is invalid. The locator %2 was not converted.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9049

An error occurred while converting the product icon.

This error may occur if the Visual Studio setup or merge module project file is corrupted or if InstallShield cannot correctly read the Visual Studio setup project file. To resolve this error, request technical support.

-9050

The project language '%1' is not installed in InstallShield. The language was not converted.

This warning occurs if you convert a Visual Studio project that includes support for a language, but InstallShield does not have built-in support for that language.

Edition • The Premier edition of InstallShield includes multilanguage support, but the Professional edition does not.

-9052

File type '%1' specifies no extensions. The file type was not converted.

This warning occurs if the Extensions property for the specified file type was left blank in the File Types Editor in Visual Studio. The warning alerts you that InstallShield could not configure the file extension during the import or conversion process.

To resolve this issue, specify one or more file extensions for the file type in Visual Studio, and then convert or import the Visual Studio project into an InstallShield project. Otherwise, you can add and configure the file extension in the Advanced Settings area of the Components view in InstallShield after you have converted or imported the Visual Studio project.

-9053

Launch condition '%1' specifies no conditions. The launch condition was not converted.

This warning occurs if the Condition property for the specified launch condition was left blank in the Launch Conditions Editor in Visual Studio. The warning alerts you that InstallShield could not configure the launch condition during the import or conversion process.

To resolve this issue, specify a condition in Visual Studio, and then convert or import the Visual Studio project into an InstallShield project. Otherwise, you can add and configure the launch condition in the General Information view in InstallShield after you have converted or imported the Visual Studio project.

-9054

File search '%1' specifies no file names. The file search was not converted.

This warning occurs if the FileName property for the specified file search was left blank in the Launch Conditions Editor in Visual Studio. The warning alerts you that InstallShield could not configure the file search during the import or conversion process.

To resolve this issue, specify the file name for the file search in Visual Studio, and then convert or import the Visual Studio project into an InstallShield project. Otherwise, you can add and configure the file search in the System Search view in InstallShield after you have converted or imported the Visual Studio project.

-9055

Feature '%1' already exists in the InstallShield project. The feature was not converted.

This warning occurs if you have a Visual Studio project that contains a particular feature and you import that project into an InstallShield project that already contains that feature. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

-9056

Directory '%1' already exists in the InstallShield project. The folder '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular folder and you import that project into an InstallShield project that already contains that folder. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Files and Folders view to ensure that the folder that is identified in the warning message is not missing from your InstallShield project.

-9057

File key '%1' already exists in the InstallShield project. The file '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a file that is associated with a particular file key and you import that project into an InstallShield project that already contains a file with that same file key. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Files area of the Components view to ensure that the file that is identified in the warning message is not missing from your InstallShield project.

Note that the Direct Editor view shows the file key that is associated with each file in your project. The file keys are the primary keys of the File table in the .msi database; the File table cannot contain duplicate file keys.

-9058

Shortcut key '%1' already exists in the InstallShield project. The shortcut '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a shortcut that is associated with a particular shortcut key and you import that project into an InstallShield project that already contains a shortcut with that same shortcut key. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Shortcuts view to ensure that the shortcut that is identified in the warning message is not missing from your InstallShield project.

-9059

Extension '%1' already exists in the InstallShield project. The file type '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular file extension and you import that project into an InstallShield project that already contains that same file extension. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Advanced Settings area of the Components view to ensure that the file extension that is identified in the warning message is not missing from your InstallShield project.

-9060

Registry key '%1' already exists in the InstallShield project. The registry entry 'Key: %2 Value: %3 Data: %4' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular registry entry and you import that project into an InstallShield project that already contains that same registry entry. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Registry view to ensure that the registry entry that is identified in the warning message is not missing from your InstallShield project.

-9061

Custom action '%1' already exists in the InstallShield project. The custom action named '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular custom action and you import that project into an InstallShield project that already contains a custom action with that same name. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Custom Actions and Sequences view to ensure that the custom action that is identified in the warning message is not missing from your InstallShield project.

-9062

Launch condition '%1' already exists in the InstallShield project. The launch condition named '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular launch condition and you import that project into an InstallShield project that already contains a launch condition with that same name. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Install Condition setting in the General Information view to ensure that the launch condition that is identified in the warning message is not missing from your InstallShield project.

-9063

RegLocator '%1' already exists in the InstallShield project. The registry search '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular registry search and you import that project into an InstallShield project that already contains a registry search with that same name. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the System Search view to ensure that the registry search that is identified in the warning message is not missing from your InstallShield project.

-9064

DrLocator '%1' already exists in the InstallShield project. The file search '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular file or folder search and you import that project into an InstallShield project that already contains a file or folder search with that same name. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the System Search view to ensure that the file or folder search that is identified in the warning message is not missing from your InstallShield project.

-9065

CompLocator '%1' already exists in the InstallShield project. The Windows Installer search '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a particular file or folder search and you import that project into an InstallShield project that already contains a file or folder search with that same name. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the System Search view to ensure that the file or folder search that is identified in the warning message is not missing from your InstallShield project.

-9070

An error occurred while converting the prerequisites.

This error occurs if you import a Visual Studio setup project that contains a prerequisite but InstallShield encounters a problem when trying to map the Visual Studio prerequisite to an equivalent InstallShield prerequisite.

To resolve this error, request technical support, or consider creating an InstallShield prerequisite that installs the required redistributable, and add that InstallShield prerequisite to your project. For more information, see Defining InstallShield Prerequisites and Working with InstallShield Prerequisites that Are Included in Installation Projects.

-9071

InstallShield has no equivalent InstallShield prerequisite for '%1'. The prerequisite was not converted.

This warning occurs if you import a Visual Studio setup project that contains a prerequisite but InstallShield does not have an equivalent InstallShield prerequisite.

To resolve this warning, consider creating an InstallShield prerequisite that installs the required redistributable, and add that InstallShield prerequisite to your project. For more information, see Defining InstallShield Prerequisites and Working with InstallShield Prerequisites that Are Included in Installation Projects.

-9074

An error occurred while converting the project outputs.

This error occurs if you convert a Visual Studio setup or merge module project that contains one or more project outputs but InstallShield encounters a problem when incorporating the project outputs into the InstallShield project.

To resolve this error, request technical support.

-9075

An error occurred while converting the project output %1. Type: %2

This error occurs if you convert a Visual Studio setup or merge module project that contains one or more project outputs but InstallShield encounters a problem when incorporating the project outputs into the InstallShield project.

To resolve this error, request technical support.

-9076

The project output type %1 is invalid. The project output %2 was not converted.

This error occurs if you convert a Visual Studio setup or merge module project that contains one or more project outputs but one of the project outputs is invalid.

To resolve this error, review the project output in your Visual Studio project, and try to resolve any issues with it. Then convert the Visual Studio project to an InstallShield project.

-9077

File key '%1' already exists in the InstallShield project. The project output '%2' was not converted.

This warning occurs if you have a Visual Studio project that contains a project output that has a file that is associated with a particular file key, and you import that project into an InstallShield project that already contains a file with that same file key. This scenario may occur if you import the same Visual Studio project into your InstallShield project more than once.

If you encounter this warning, check the Files and Folders view to ensure that the file that is identified in the warning message is not missing from your InstallShield project.

Note that the Direct Editor view shows the file key that is associated with each file in your project. The file keys are the primary keys of the File table in the .msi database; the File table cannot contain duplicate file keys.

-9078

The InstallShield project is not in a Visual Studio solution. The project output '%1' was not converted.

This error occurs if your InstallShield project is open in InstallShield, but not from within Visual Studio, and you try to import a Visual Studio project that contains project outputs into the InstallShield project.

To resolve this error, open your InstallShield project from within Visual Studio, and then import the Visual Studio project into it.

-9079

The Visual Studio project '%1' could not be found in the current Visual Studio solution. The project output '%2' was not converted.

If you want to import into an InstallShield project a Visual Studio setup or merge module project that contains a project output, the Visual Studio project must be in the same solution as all of its project dependencies. Otherwise, this error occurs when you try to import the Visual Studio project.

To resolve this error, ensure that your InstallShield project is in the same Visual Studio solution that contains the Visual Studio setup or merge module project that you are importing. In addition, ensure that the solution also includes all of the other Visual Studio projects that are dependencies of the Visual Studio setup or merge module project. Then you can import the Visual Studio setup or merge module project into your InstallShield project.

-9080

The project output group '%1' could not be found in the Visual Studio project '%2'. The project output '%3' was not converted.

This error occurs if you convert a Visual Studio setup or merge module project that contains a project output group but InstallShield encounters a problem when incorporating a project output of that group into the InstallShield project.

To resolve this error, request technical support.

-9081

File '%1' is specified to be excluded from a setup or merge module. The file was not converted.

This warning occurs if you import into an InstallShield project a Visual Studio setup or merge module project that contains a file whose Exclude property is set to True.

If you want the specified file to be excluded from your InstallShield project, you can ignore this warning.

If you want the specified file to be included in your InstallShield project, you can use the Files and Folders view in InstallShield to add it. For more information, see Adding to Your Project Files to Be Installed on Target Systems.

-9082

Project output '%1' is specified to be excluded from a setup or merge module. The project output was not converted.

This warning occurs if you import into an InstallShield project a Visual Studio setup or merge module project that contains a file in a project output, and True is selected for the Exclude property of that file.

If you want the specified file to be excluded from your InstallShield project, you can ignore this warning.

If you want the specified file to be included in your InstallShield project, you can use the Files and Folders view in InstallShield to add it. For more information, see Adding References to Visual Studio Solutions.

-9083

Visual Studio default launch conditions are not supported in InstallShield. The launch condition named '%1' was not converted.

This warning occurs if you import into InstallShield project a Visual Studio setup or merge module project that contains a default launch condition.

If you want the specified launch condition to be excluded from your InstallShield project, you can ignore this warning.

If you want to add a launch condition to your InstallShield project to check the target system for the default launch condition that Visual Studio added to the original project, you can use the System Search view in InstallShield to add it. For more information, see Adding a System Search.

-9086

MinDate '%1' for the file search named '%2' is not valid. The MinDate property was not converted.

This warning occurs if you attempt to import or convert a Visual Studio setup that has a file search with an invalid value for the MinDate property.

To resolve this warning:

1. Open the System Search view in InstallShield.
2. Right-click the file search and then click Modify. The System Search Wizard opens.
3. On the second panel of this wizard, click the Details button. The File Details dialog box opens.
4. Enter the appropriate details.

-9087

MaxDate '%1' for the file search named '%2' is not valid. The MaxDate property was not converted.

This warning occurs if you attempt to import or convert a Visual Studio setup that has a file search with an invalid value for the MaxDate property.

To resolve this warning:

1. Open the System Search view in InstallShield.
2. Right-click the file search and then click Modify. The System Search Wizard opens.
3. On the second panel of this wizard, click the Details button. The File Details dialog box opens.
4. Enter the appropriate details.

-9088

InstallShield does not have support for converting Visual Studio Web Setup projects into InstallShield projects.

This error occurs if you attempt to import or convert a Visual Studio Web setup project in InstallShield, since InstallShield does not have support for this conversion. If you encounter this type of error, consider creating a new project in InstallShield and using the Internet Information Services view to manage an IIS Web site on a target system.

-9089

InstallShield does not have support for converting Visual Studio CAB projects into InstallShield projects.

This error occurs if you attempt to import or convert a Visual Studio CAB setup project in InstallShield, since InstallShield does not have support for this conversion.

-9090

The Visual Studio project type could not be identified. Therefore, the project was not converted.

This error occurs if you attempt to attempt to import or convert a Visual Studio project type that InstallShield could not identify.

-10000

Conversion canceled by user.

This error occurs if you cancel the conversion process before it finishes.

See Also